Instructions
Table Of Contents
- Guaranty and Declaration
- Safety Requirement
- MSO5000-E Series Overview
- Document Overview
- Quick Start
- General Inspection
- Appearance and Dimensions
- To Prepare for Use
- Front Panel Overview
- Rear Panel Overview
- Front Panel Function Overview
- User Interface
- Touch Screen Controls
- Parameter Setting Method
- To Use the Kensington Security Lock
- To Use the Built-in Help System
- To View the Option Information and the Option Installation
- To Set the Vertical System
- To Set the Horizontal System
- To Set the Sample System
- To Trigger the Oscilloscope
- Trigger Source
- Trigger LEVEL/Threshold Level
- Trigger Mode
- Trigger Coupling
- Trigger Holdoff
- Noise Rejection
- Trigger Type
- Edge Trigger
- Pulse Trigger
- Slope Trigger
- Video Trigger
- Pattern Trigger
- Duration Trigger
- Timeout Trigger
- Runt Trigger
- Window Trigger
- Delay Trigger
- Setup/Hold Trigger
- Nth Edge Trigger
- RS232 Trigger (Option)
- I2C Trigger (Option)
- SPI Trigger (Option)
- CAN Trigger (Option)
- FlexRay Trigger (Option)
- LIN Trigger (Option)
- I2S Trigger (Option)
- MIL-STD-1553 Trigger (Option)
- Zone Trigger
- Trigger Output Connector
- Operations and Measurements
- Digital Voltmeter (DVM) and Frequency Counter
- Power Analysis (Option)
- Histogram Analysis
- Digital Channel
- Protocol Decoding
- Reference Waveform
- To Enable Ref Function
- To Select the Reference Channel
- To Select the Ref Source
- To Adjust the Ref Waveform Display
- To Save to Internal Memory
- To Clear the Display of the Reference Waveform
- To View Details of the Reference Waveform
- To Reset the Reference Waveform
- Color Setting
- Label Setting
- To Export to Internal or External Memory
- To Import from Internal or External Memory
- Pass/Fail Test
- Waveform Recording & Playing
- Search and Navigation Function
- Display Control
- Function/Arbitrary Waveform Generator (Option)
- Store and Load
- System Utility Function Setting
- Remote Control
- Troubleshooting
- Appendix
- Index

RIGOL Chapter 6 Operations and Measurements
6-8 MSO5000-E User Guide
the frequency at the right side of the screen. Press End to set the stop
frequency of the frequency-domain waveform. For setting methods, refer to
descriptions in "
Parameter Setting Method".
Press More Peak Search to enter the peak search menu.
Press Peak Search continuously to enable or disable the peak search function.
When enabled, the peak search results are displayed on the screen, as shown in
the figure below. Enable the touch screen and tap the "Math" label at the top of
the peak search results to switch among Math1-Math4.
Press Peak Number, then rotate the multifunction knob or use the
pop-up numeric keypad to set the number of peaks. The available range is
from 1 to 15. By default, it is 5.
Press Threshold, then rotate the multifunction knob or use the pop-up
numeric keypad to set the threshold of the peak.
Press Excursion, then rotate the multifunction knob or use the pop-up
numeric keypad to set the excursion of the peak.
Press Table Order, then rotate the multifunction knob to select the
sorting mode of the peak. Press down the knob to select it. You can also
press Table Order continuously or enable the touch screen to select it. The
available sorting mode is "Amp Order" and "Freq Order". By default, it is
"Amp Order".
Press Export, and the save setting menu is displayed. You can export the
peak search results to the internal memory or the external USB storage
device in CSV format. For detailed saving operation, refer to descriptions in
"
Store and Load".
Press More Window to select the desired window function.
Spectral leakage can be considerably decreased when a window function is used.
MSO5000-E series provides 6 FFT window functions (as shown in Table 6-1)
which have different characteristics and are applicable to measuring different
waveforms. You need to select the window function according to the
characteristics of the waveform to be measured.