Instructions
Chapter 2 Command System  RIGOL 
MSO5000-E Programming Guide  2-209  
:TRIGger:FLEXray (Option) 
Command List: 
  :TRIGger:FLEXray:BAUD 
  :TRIGger:FLEXray:LEVel 
  :TRIGger:FLEXray:SOURce 
  :TRIGger:FLEXray:WHEN 
:TRIGger:FLEXray:BAUD 
Syntax  :TRIGger:FLEXray:BAUD <baud> 
:TRIGger:FLEXray:BAUD? 
Description 
Sets or queries the signal rate of FlexRay trigger. The default unit is bps. 
Parameter 
Name 
Type 
Range 
Default 
<baud> 
Discrete 
{2500000|5000000|10000000} 
10000000 bps 
Return 
Format 
The query returns 2500000, 5000000, or 10000000. 
Example 
:TRIGger:FLEXray:BAUD 5000000 /*Sets the signal rate to 5000000 bps.*/ 
:TRIGger:FLEXray:BAUD?  /*The query returns 5000000.*/ 
:TRIGger:FLEXray:LEVel 
Syntax  :TRIGger:FLEXray:LEVel <level> 
:TRIGger:FLEXray:LEVel? 
Description  Sets or queries the trigger level of FlexRay trigger. Its unit is the same as that of the 
current amplitude. 
Parameter 
Name 
Type 
Range 
Default 
<level>  Real 
(-5 × VerticalScale - OFFSet) to  
(5 × VerticalScale - OFFSet) 
0 V 
Remarks  For VerticalScale, refer to the :CHANnel<n>:SCALe command; for OFFSet, refer to 
the :CHANnel<n>:OFFSet command. 
Return 
Format 
The query returns the trigger level in scientific notation. 
Example 
:TRIGger:FLEXray:LEVel 0.16    /*Sets the trigger level to 160 mV.*/ 
:TRIGger:FLEXray:LEVel?  /*The query returns 1.600000E-1.*/ 