Instructions
RIGOL  Chapter 12 Reference Waveform 
12-2  MSO5000 User's Guide 
To Enable Ref Function 
Press Ref on the front panel to enable the reference waveform function, or enable 
the  touch  screen  and  then  tap  the  function  navigation  icon    at  the  lower-left 
corner of the screen to open the function navigation.  Then, tap the "Ref" icon to 
enable the reference waveform function. 
When the Ref function is enabled, you can select a different color for each reference 
waveform, set the source of each reference channel, adjust the vertical scale and 
offset of the reference waveform, save the reference waveform to the internal or 
external memory, and recall it when needed.   
Note: When the horizontal time base is set to XY, the reference waveform function is 
disabled. 
To Select the Reference Channel 
Press Current, rotate the multifunction knob    to select the desired reference 
waveform channel (Ref1-Ref10). You can also press Current continuously or enable 
the touch screen to select the reference waveform channel. By default, Ref1 is 
enabled. 
To Select the Ref Source 
Press Source, rotate the multifunction knob    to select the desired reference 
waveform source (CH1-CH4, D0-D15, or Math1-Math4). You can also press Source 
continuously or enable the touch screen to select the reference waveform source. 
Note: Only the currently enabled channel can be selected as the source channel of 
the reference waveform. 
To Adjust the Ref Waveform Display 
After pressing SaveToRef, you can adjust the vertical scale and offset of the 
reference waveform specified under Current. 
  Press VScale, then rotate the multifunction knob    or use the pop-up 
numeric keypad to set the vertical scale of the reference waveform. You can also 
enable the touch screen and use the "Pinch & Stretch" gesture to adjust the 
vertical scale. 