Instructions
RIGOL  Chapter 11 Protocol Decoding 
11-12  MSO5000 User's Guide 
the top of the event table to select it. 
If you select "Packets", the time and decoded data are displayed in the 
event table; if you select "Details", the detailed data in the specified 
row will be displayed in the event table; if you select "Payload", all data 
in the specified column will be displayed in the event table.   
  Export: If you select "Packets", you can export time, the corresponding 
decoded data, and etc. Press Export, the save setting menu is 
displayed. You can export the data table of the packets to the internal 
or external USB storage device (when detected) in CSV format. For 
detailed saving operation, refer to descriptions in "Store and Load". 
  Jump to: Set the operating status of the oscilloscope to "STOP". Then, 
select the data of the specified time from the event table. Press Jump 
to and the specified data waveforms are displayed in the center of the 
screen. 
  Decode: The setting of this menu enables you to quickly view the 
corresponding event tables of four decode modules (Decode1, 
Decode2, Decode3, and Decode4). Press Decode and rotate the 
multifunction knob    to select a decode module, then press down 
the knob to select it. You can also press Decode continuously or 
enable the touch screen to select it. 
7. Error expressions in decoding 
In RS232 decoding, parity error and/or EOF (end of frame) error may occur. 
  Parity Error 
When a parity error is detected during the decoding, red error report 
information will be displayed. For example, when "none" is chosen for the 
parity on the transmitter and "odd" is chosen for the parity on the decoder, 
the following parity error information    (its display form is related to the 
value of the horizontal time base) occurs. Wherein, the number of 1s in the 
8-digit figure (00000100) is an odd number, and the parity bit should be 0. 
However, the parity bit detected on the Tx is 1; thus a parity error occurs. 