Instructions
Chapter 10 Digital Channel    RIGOL 
MSO5000 User's Guide  10-3 
  Enable/disable a single digital channel 
Press Dx On/Off to open the channel selection list. Rotate the multifunction 
knob    to select a channel, and then press down the knob to enable or disable 
it. You can also press Dx On/Off continuously to switch to select any channel, 
and press down the multifunction knob    to enable or disable the channel. 
You can also enable the touch screen to enable or disable the selected channel. 
Besides, you can also enable the touch screen to tap the digital channel status 
area at the bottom of the screen. Then, the LA window is displayed. In the 
window, you can select the LA channel and set the threshold. Tap a single 
channel to enable or disable the channel. 
Note: While pressing D7-D0 to disable all the channels D7-D0, you can still 
disable or enable any channel among D7-D0 through the Dx On/Off key. While 
pressing D7-D0 to enable D7-D0, the D0-D7 channels under Dx On/Off are 
enabled automatically. The same is true for D15-D8 channels. 
  Enable or disable user-defined channel group 
Press  Group  On/Off,  then  rotate  the  multifunction  knob    to  select  the 
specified  channel  group.  Press  down  the  knob  to  enable  or  disable  all  the 
channels in this channel group. You can also enable the touch screen to tap the 
specified group and select it. The enabled channel groups are marked with  , 
and the disabled channel groups are marked with  . 
Note: This function is only valid when the channels have been grouped by users. 
For how to carry out group settings, refer to descriptions in "Group Setting". 
To Set the Threshold and Calibrate Probe 
  Threshold Setting 
The  threshold  levels  of  channels  D7-D0  and  channels  D15-D8  can  be  set 
separately according  to  your  needs. Press  Threshold  to  enter  the  threshold 
setting menu. When the voltage of the input signal is greater than the currently 
set threshold, it is treated as logic 1; otherwise, it is treated as logic 0. 
Press D7-D0 or D15-D8 respectively to open the threshold selection list and 
select  the  preset  threshold.  The  available  preset  values  include  TTL(1.40  V), 
CMOS5.0(2.5  V),  CMOS3.3(1.65  V),  CMOS2.5(1.25  V),  CMOS1.8(0.9  V), 
ECL(-1.3 V), PECL(3.7 V), LVDS(1.2 V), and 0 V. You can also press D7-D0 or 
D15-D8  respectively,  then  rotate  the  multifunction  knob    at  a  small  step 
value or use the pop-up numeric keypad to set the desired threshold. 
Besides, you can also enable the touch screen to tap the digital channel status 
area  at the  bottom  of  the  screen.  Then, the  LA  window  is displayed.  In  the 
window, you can select the LA channel and set the threshold. Tap the    icon 
at the right side of the threshold field, and then the threshold selection list is 