Instructions
Chapter 6 Operations and Measurements    RIGOL 
MSO5000 User's Guide  6-33 
Note: 
  Source A and Source B can be any channel among CH1-CH4, Math1-Math4, or 
D0-D15.  You  can  press  Measure    Add  to  enter  the  sub-menu  to  set  the 
parameters. 
  The default threshold middle value is 50%. You can press Measure  Setting 
to enter the sub-menu to set the parameters. 
Voltage Parameters 
Figure 6-2 Voltage Parameters 
1. Vmax: indicates the voltage value from the highest point of the waveform to 
the GND. 
2. Vmin: indicates the voltage value from the lowest point of the waveform to the 
GND. 
3. Vpp: the voltage value from the highest point to the lowest point of the 
waveform. 
4. Vtop: indicates the voltage value from the flat top of the waveform to the GND. 
5. Vbase: indicates the voltage value from the flat base of the waveform to the 
GND. 
6. Vamp: indicates the voltage value from the top of the waveform to the base of 
the waveform. 
7. Vupper: indicates the actual voltage value that corresponds to the threshold 
maximum value. 
8. Vmid: indicates the actual voltage value that corresponds to the threshold 
middle value. 
9. Vlower: indicates the actual voltage value that corresponds to the threshold 
minimum value. 
10.   Vavg: indicates the arithmetic average value on the whole waveform or in the 
Preshoot 
Overshoot 
Vamp 
Vbase 
Vmax 
Vmin 
Vpp 
Vtop 
Vupper 
Vmid 
Vlower 