Instructions
Chapter 2 Command System  RIGOL 
MSO5000 Programming Guide  2-219   
:TRIGger:LIN:BAUD 
Syntax 
:TRIGger:LIN:BAUD <baud> 
:TRIGger:LIN:BAUD? 
Description 
Sets or queries the baud rate of LIN trigger. The default unit is bps. 
Parameter 
Name 
Type 
Range 
Default 
<baud> 
Integer 
1 kbps to 20 Mbps 
9600 bps 
Remarks 
If the baud rate is set to a value with "M", then "A" should be added at the end of the 
value. For example, if you send 5 M, you need to send 5 MA. 
Return 
Format 
The query returns an integer ranging from 1 kbps to 20 Mbps. 
Example 
:TRIGger:LIN:BAUD 19200        /*Sets the baud rate of LIN trigger to 19200 bps.*/ 
:TRIGger:LIN:BAUD?                /*The query returns 19200.*/ 
:TRIGger:LIN:STANdard 
Syntax 
:TRIGger:LIN:STANdard <std> 
:TRIGger:LIN:STANdard? 
Description 
Sets or queries the protocol version of LIN trigger. 
Parameter 
Name 
Type 
Range 
Default 
<std> 
Discrete 
{1X|2X} 
1X 
Return Format 
The query returns 1X or 2X. 
Example 
:TRIGger:LIN:STANdard 2X        /*Sets the protocol version of LIN trigger to 2X.*/ 
:TRIGger:LIN:STANdard?            /*The query returns 2X.*/ 
:TRIGger:LIN:SAMPlepoint 
Syntax 
:TRIGger:LIN:SAMPlepoint <value> 
:TRIGger:LIN:SAMPlepoint? 
Description 
Sets or queries the sample position of LIN trigger. 
Parameter 
Name 
Type 
Range 
Default 
<value> 
Integer 
10 to 90 
50 
Description 
The sample position is expressed as the ratio of "time from the bit start to the sample 
point" to "bit time", in %. 
Return Format 
The query returns an integer ranging from 10 to 90. 
Example 
:TRIGger:LIN:SAMPlepoint 40   
/*Sets the sample point position of LIN trigger to 40%.*/ 
:TRIGger:LIN:SAMPlepoint?     
/*The query returns 40.*/ 