Instructions
RIGOL  Chapter 2 Command System 
2-210    MSO5000 Programming Guide 
:TRIGger:SPI:DLEVel 
Syntax 
:TRIGger:SPI:DLEVel <level> 
:TRIGger:SPI:DLEVel? 
Description 
Sets or queries the trigger level of the data channel of SPI trigger. The unit is the 
same as that of the current amplitude. 
Parameter 
Name 
Type 
Range 
Default 
<level> 
Real 
(-5 ×  VerticalScale - OFFSet) to   
(7 ×  VerticalScale - OFFSet) 
0 V 
Remarks 
For VerticalScale, refer to the :CHANnel<n>:SCALe command; for OFFSet, refer to 
the :CHANnel<n>:OFFSet command. 
Return 
Format 
The query returns the trigger level in scientific notation. 
Example 
:TRIGger:SPI:DLEVel 0.16        /*Sets the trigger level to 160 mV.*/ 
:TRIGger:SPI:DLEVel?              /*The query returns 1.600000E-1.*/ 
:TRIGger:SPI:SLEVel 
Syntax 
:TRIGger:SPI:SLEVel <level> 
:TRIGger:SPI:SLEVel? 
Description 
Sets or queries the trigger level of the CS channel of SPI trigger. The unit is the same 
as that of the current amplitude. 
Parameter 
Name 
Type 
Range 
Default 
<level> 
Real 
(-5 ×  VerticalScale - OFFSet) to   
(7 ×  VerticalScale - OFFSet) 
0 V 
Remarks 
For VerticalScale, refer to the :CHANnel<n>:SCALe command; for OFFSet, refer to 
the :CHANnel<n>:OFFSet command. 
Return 
Format 
The query returns the trigger level in scientific notation. 
Example 
:TRIGger:SPI:SLEVel 0.16        /*Sets the trigger level to 160 mV.*/ 
:TRIGger:SPI:SLEVel?              /*The query returns 1.600000E-1.*/ 
:TRIGger:SPI:MODE 
Syntax 
:TRIGger:SPI:MODE <mode> 
:TRIGger:SPI:MODE? 
Description 
Sets or queries the CS mode of SPI trigger when the trigger condition is "CS". 
Parameter 
Name 
Type 
Range 
Default 
<mode> 
Discrete 
{HIGH|LOW} 
LOW 
Return 
Format 
The query returns HIGH or LOW. 
Example 
:TRIGger:SPI:MODE LOW      /*Sets the CS mode to low level.*/ 
:TRIGger:SPI:MODE?              /*The query returns LOW.*/ 