Instructions
RIGOL  Chapter 2 Command System 
2-152    MSO5000 Programming Guide 
  VSCale3: press down the vertical scale knob of CH3, i.g. switch the vertical scale of 
CH3 to "Coarse" or "Fine". 
  VSCale4: press down the vertical scale knob of CH4, i.g. switch the vertical scale of 
CH4 to "Coarse" or "Fine". 
  GENerator1|GENerator2: press down AWG1 or AWG2. 
  HSCale: press down the horizontal time base adjustment knob, i.g. switch the 
horizontal time base to "Coarse" or "Fine". 
  HPOSition: press down the horizontal position knob, i.g. set the horizontal position to 
0. 
  KFUNction: press down the multifunction knob. 
  TLEVel: press down the trigger level adjustment knob, i.g. set the trigger level to 
50% of the peak-peak value. 
  TMENu: press the MENU key in the trigger control area. 
  TMODe: press the MODE key in the trigger control area. 
  RSTop: press the RUN/STOP key. 
Example 
:SYSTem:KEY:PRESs <CH1>/*Press the CH1 key on the front panel of the oscilloscope.*/ 
:SYSTem:KEY:INCRease 
:SYSTem:KEY:DECRease 
Syntax 
:SYSTem:KEY:INCRease <key>[,<val>] 
:SYSTem:KEY:DECRease <key>[,<val>] 
Description 
Rotate the specified knob clockwise. 
Rotate the specified knob counterclockwise. 
Parameter 
Name 
Type 
Range 
Default 
<key> 
Discrete 
{VOFFset1|VOFFset2|VOFFset3|VOFFset4| 
VSCale1|VSCale2|VSCale3|VSCale4|HSCale| 
HPOSition|KFUNction|TLEVel} 
—— 
<val> 
Integer 
Determined by the range of the parameter 
<key> and the current setting of the 
parameter. 
1 
Remarks 
  The value of the parameter <key> corresponds to the specified knob on the front 
panel. The definitions for the knob are as follows: 
VOFFset1: the CH1 vertical offset knob. 
VOFFset2: the CH2 vertical offset knob. 
VOFFset3: the CH3 vertical offset knob. 
VOFFset4: the CH4 vertical offset knob. 
VSCale1: the vertical scale adjustment knob of CH1. 
VSCale2: the vertical scale adjustment knob of CH2. 
VSCale3: the vertical scale adjustment knob of CH3. 
VSCale4: the vertical scale adjustment knob of CH4. 
HSCale: the horizontal time base adjustment knob. 
HPOSition: the horizontal position adjustment knob. 
KFUNction: the multifunction knob. 
TLEVel: the trigger level adjustment knob. 
  The parameter <val> defines the specified rotation times of the knob. By default, 