User Manual
Table Of Contents
- Guaranty and Declaration
- Safety Requirement
- MSO2000A/DS2000A Series Overview
- Document Overview
- Chapter 1 Quick Start
- Chapter 2 To Set the Vertical System
- Chapter 3 To Set the Horizontal System
- Chapter 4 To Set the Sample System
- Chapter 5 To Trigger the Oscilloscope
- Trigger Source
- Trigger Mode
- Trigger Coupling
- Trigger Holdoff
- Noise Rejection
- Trigger Type
- Edge Trigger
- Pulse Trigger
- Runt Trigger
- Windows Trigger (Option)
- Nth Edge Trigger (Option)
- Slope Trigger
- Video Trigger (HDTV Option)
- Pattern Trigger
- Delay Trigger (Option)
- TimeOut Trigger (Option)
- Duration Trigger (Option)
- Setup/Hold Trigger
- RS232 Trigger
- I2C Trigger
- SPI Trigger
- USB Trigger (Option)
- CAN Trigger (Option)
- Trigger Output Connector
- Chapter 6 MATH and Measurements
- Chapter 7 Digital Channel
- Chapter 8 Protocol Decoding
- Chapter 9 Reference Waveform
- Chapter 10 Pass/Fail Test
- Chapter 11 Waveform Record
- Chapter 12 Display Control
- Chapter 13 Signal Source
- Chapter 14 Store and Recall
- Chapter 15 System Function Setting
- Chapter 16 Remote Control
- Chapter 17 Troubleshooting
- Chapter 18 Specifications
- Chapter 19 Appendix
- Index
RIGOL Chapter 15 System Function Setting
MSO2000A/DS2000A User’s Guide
15-4
1. Set the IP Address
The format of IP address is nnn.nnn.nnn.nnn; wherein, the range of the first
nnn is from 1 to 223 (except 127) and the ranges of the other three nnn are
from 0 to 255. You are recommended to ask your network administrator for an
IP address available.
Press IP Address and use to input the desired IP address. This setting will
be saved in the non-volatile memory and if “Power-off Recall” is set to “Last”
and “DHCP” and “Auto IP” are “Off” at the next power-on, the oscilloscope will
load the preset IP address automatically.
2. Set the Subnet Mask
The format of the subnet mask is nnn.nnn.nnn.nnn; wherein, the ranges of the
nnn are from 0 to 255. You are recommended to ask your network administrator
for a subnet mask available.
Press Mask and use to input the desired subnet mask. This setting will be
saved in the non-volatile memory and if “Power-off Recall” is set to “Last” and
“DHCP” and “Auto IP” are “Off” at the next power-on, the oscilloscope will load
the preset subnet mask automatically.
Set the Gate
You can set this paramter in Auto IP and Static IP mode.
The format of the gate is nnn.nnn.nnn.nnn; wherein, the range of the first nnn is
from 1 to 223 (except 127) and the ranges of the other three nnn are from 0 to 255.
You are recommended to ask your network administrator for a gate address
available.
Press Gate and use to input the desired gate address. This setting will be saved
in the non-volatile memory and if “Power-off Recall” is set to “Last” and “DHCP”
and “Auto IP” are “Off” at the next power-on, the oscilloscope will load the preset
gate address automatically.