User Manual
Table Of Contents
- Guaranty and Declaration
- Safety Requirement
- MSO2000A/DS2000A Series Overview
- Document Overview
- Chapter 1 Quick Start
- Chapter 2 To Set the Vertical System
- Chapter 3 To Set the Horizontal System
- Chapter 4 To Set the Sample System
- Chapter 5 To Trigger the Oscilloscope
- Trigger Source
- Trigger Mode
- Trigger Coupling
- Trigger Holdoff
- Noise Rejection
- Trigger Type
- Edge Trigger
- Pulse Trigger
- Runt Trigger
- Windows Trigger (Option)
- Nth Edge Trigger (Option)
- Slope Trigger
- Video Trigger (HDTV Option)
- Pattern Trigger
- Delay Trigger (Option)
- TimeOut Trigger (Option)
- Duration Trigger (Option)
- Setup/Hold Trigger
- RS232 Trigger
- I2C Trigger
- SPI Trigger
- USB Trigger (Option)
- CAN Trigger (Option)
- Trigger Output Connector
- Chapter 6 MATH and Measurements
- Chapter 7 Digital Channel
- Chapter 8 Protocol Decoding
- Chapter 9 Reference Waveform
- Chapter 10 Pass/Fail Test
- Chapter 11 Waveform Record
- Chapter 12 Display Control
- Chapter 13 Signal Source
- Chapter 14 Store and Recall
- Chapter 15 System Function Setting
- Chapter 16 Remote Control
- Chapter 17 Troubleshooting
- Chapter 18 Specifications
- Chapter 19 Appendix
- Index
RIGOL Chapter 9 Reference Waveform
9-2 MSO2000A/DS2000A User’s Guide
To Enable REF Function
Press REF in the vertical control area (VERTICAL) at the front panel to enable the
REF function.
Note: When the time base is in X-Y mode, REF function cannot be enabled.
MSO2000A/DS2000A provides 10 reference waveform channels. Press Channel,
rotate to select the desired reference channel and press down or Channel
to turn the selected channel on or off. A channel icon (for example,
) of the
channel enabled will be displayed at the left side of the screen grid.
When the REF function is enabled, you can select different color for each reference
waveform, set the source of each reference channel, adjust the vertical scale and
position of the reference waveform and save the reference waveform to internal or
external memory as well as recall it when needed. For the details, please refer to the
introductions below.
To Set the Color
MSO2000A/DS2000A series oscilloscope provides five colors (gray, green, light blue,
magenta and orange) to mark the reference waveforms of different channels in order
to distinguish them.
Press Current and use to select any of the reference channels (Ref1-Ref10)
enabled. Then, press Color to specify a different color for the reference waveform of
that channel. The corresponding icon at the left of the channel currently selected will
be filled with the specified color, for example,
.
To Select REF Source
Press Current and use to select any of the reference channels (Ref1 to Ref10)
enabled and then press Source to specify a reference source (CH1, CH2, MATH or
any channel of D0-D15) for this channel. Only the channels currently enabled can be
selected.