User Manual
Table Of Contents
- Guaranty and Declaration
- Safety Requirement
- MSO2000A/DS2000A Series Overview
- Document Overview
- Chapter 1 Quick Start
- Chapter 2 To Set the Vertical System
- Chapter 3 To Set the Horizontal System
- Chapter 4 To Set the Sample System
- Chapter 5 To Trigger the Oscilloscope
- Trigger Source
- Trigger Mode
- Trigger Coupling
- Trigger Holdoff
- Noise Rejection
- Trigger Type
- Edge Trigger
- Pulse Trigger
- Runt Trigger
- Windows Trigger (Option)
- Nth Edge Trigger (Option)
- Slope Trigger
- Video Trigger (HDTV Option)
- Pattern Trigger
- Delay Trigger (Option)
- TimeOut Trigger (Option)
- Duration Trigger (Option)
- Setup/Hold Trigger
- RS232 Trigger
- I2C Trigger
- SPI Trigger
- USB Trigger (Option)
- CAN Trigger (Option)
- Trigger Output Connector
- Chapter 6 MATH and Measurements
- Chapter 7 Digital Channel
- Chapter 8 Protocol Decoding
- Chapter 9 Reference Waveform
- Chapter 10 Pass/Fail Test
- Chapter 11 Waveform Record
- Chapter 12 Display Control
- Chapter 13 Signal Source
- Chapter 14 Store and Recall
- Chapter 15 System Function Setting
- Chapter 16 Remote Control
- Chapter 17 Troubleshooting
- Chapter 18 Specifications
- Chapter 19 Appendix
- Index
Chapter 6 MATH and Measurements RIGOL
MSO2000A/DS2000A User’s Guide 6-13
2. Channel
You can select any channel of CH1 and CH2 or select both of the two channels.
3. Function
The functions of the functions are listed in the following table.
Note: The left brackets “(” here are only used to facilitate your entry and they
are not a part of the function names.
Table 6-3 Functions
Name Function
Intg( Calculate the integral of the selected source. You can use integral
to measure the area under a waveform or the pulse energy.
Diff( Calculate the discrete time differential of the selected source. You
can use differential to measure the instantaneous slope of a
waveform.
Lg( Calculate the common logarithm of the selected source (use 10 as
the base).
Exp( Calculate the exponent of the selected source. For example,
Exp(A) means calculate the Ath power of e.
Sqrt( Calculate the square root of the selected source.
Sine( Calculate the sine value of the selected source.
Cosine( Calculate the cosine value of the selected source.
Tangent( Calculate the tangent value of the selected source.
4. Variable
Users can set the desired values of Variable1 and Variable2 using the following
method.
Press Variable to turn on the variable setting menu.
Variable: press this softkey to select the variable to be set as “Variable1”
and “Variable2”.
Step: press this softkey to set the step used when using
to modify the
“Mantissa”. The steps available are × 1, × 0.1, × 0.01, × 0.001 and ×
0.0001.
Mantissa: press this softkey and turn
to modify the mantissa at the
step specified in Step. The range available is from -9.9999 to 9.9999.
Exponent: press this softkey to set the numeric values of the exponents
with 10 as the bottom number in the variables. The range is from -9 to 9.