User Manual
Table Of Contents
- Guaranty and Declaration
- Safety Requirement
- MSO2000A/DS2000A Series Overview
- Document Overview
- Chapter 1 Quick Start
- Chapter 2 To Set the Vertical System
- Chapter 3 To Set the Horizontal System
- Chapter 4 To Set the Sample System
- Chapter 5 To Trigger the Oscilloscope
- Trigger Source
- Trigger Mode
- Trigger Coupling
- Trigger Holdoff
- Noise Rejection
- Trigger Type
- Edge Trigger
- Pulse Trigger
- Runt Trigger
- Windows Trigger (Option)
- Nth Edge Trigger (Option)
- Slope Trigger
- Video Trigger (HDTV Option)
- Pattern Trigger
- Delay Trigger (Option)
- TimeOut Trigger (Option)
- Duration Trigger (Option)
- Setup/Hold Trigger
- RS232 Trigger
- I2C Trigger
- SPI Trigger
- USB Trigger (Option)
- CAN Trigger (Option)
- Trigger Output Connector
- Chapter 6 MATH and Measurements
- Chapter 7 Digital Channel
- Chapter 8 Protocol Decoding
- Chapter 9 Reference Waveform
- Chapter 10 Pass/Fail Test
- Chapter 11 Waveform Record
- Chapter 12 Display Control
- Chapter 13 Signal Source
- Chapter 14 Store and Recall
- Chapter 15 System Function Setting
- Chapter 16 Remote Control
- Chapter 17 Troubleshooting
- Chapter 18 Specifications
- Chapter 19 Appendix
- Index
Chapter 6 MATH and Measurements RIGOL
MSO2000A/DS2000A User’s Guide 6-3
Press Label to define a label for the operation results. For the details, please
refer to “
MATH Label”.
HORIZONTAL
POSITION and HORIZONTAL SCALE can also be
used to adjust the horizontal position and scale of the operation results.
Multiplication
Multiply the waveform voltage values of signal source A and B point by point and
display the results. Press MATH Operate to select “A x B”:
Press Source A and Source B respectively to select the desired channels (CH1
or CH2).
Press and use to adjust the vertical position of the operation results.
Press
and use to adjust the vertical scale of the operation results.
Press Invert to turn the inverted display of the operation results on or off.
Press Label to define a label for the operation results. For the details, please
refer to “
MATH Label”.
HORIZONTAL
POSITION and HORIZONTAL SCALE can also be
used to adjust the horizontal position and scale of the operation results.
Division
Divide the waveform voltage values of signal source A by that of source B point by
point and display the results. It can be used to analyze the multiple relationships of
waveforms in the two channels.
Note: When the waveform voltage value of signal source B is 0, the result of the
division is treated as 0.
Press MATH Operate to select “A ÷ B”:
Press Source A and Source B respectively to select the desired channels (CH1
or CH2).
Press and use to adjust the vertical position of the operation results.
Press
and use to adjust the vertical scale of the operation results.
Press Invert to turn the inverted display of the operation results on or off.
Press Label to define a label for the operation results. For the details, please