User Manual
Table Of Contents
- Guaranty and Declaration
- Safety Requirement
- MSO2000A/DS2000A Series Overview
- Document Overview
- Chapter 1 Quick Start
- Chapter 2 To Set the Vertical System
- Chapter 3 To Set the Horizontal System
- Chapter 4 To Set the Sample System
- Chapter 5 To Trigger the Oscilloscope
- Trigger Source
- Trigger Mode
- Trigger Coupling
- Trigger Holdoff
- Noise Rejection
- Trigger Type
- Edge Trigger
- Pulse Trigger
- Runt Trigger
- Windows Trigger (Option)
- Nth Edge Trigger (Option)
- Slope Trigger
- Video Trigger (HDTV Option)
- Pattern Trigger
- Delay Trigger (Option)
- TimeOut Trigger (Option)
- Duration Trigger (Option)
- Setup/Hold Trigger
- RS232 Trigger
- I2C Trigger
- SPI Trigger
- USB Trigger (Option)
- CAN Trigger (Option)
- Trigger Output Connector
- Chapter 6 MATH and Measurements
- Chapter 7 Digital Channel
- Chapter 8 Protocol Decoding
- Chapter 9 Reference Waveform
- Chapter 10 Pass/Fail Test
- Chapter 11 Waveform Record
- Chapter 12 Display Control
- Chapter 13 Signal Source
- Chapter 14 Store and Recall
- Chapter 15 System Function Setting
- Chapter 16 Remote Control
- Chapter 17 Troubleshooting
- Chapter 18 Specifications
- Chapter 19 Appendix
- Index
RIGOL Chapter 5 To Trigger the Oscilloscope
5-44 MSO2000A/DS2000A User’s Guide
SPI Trigger
Trigger on the data pattern on the specified edge. When using SPI trigger, you need
to specify the SCL and SDA data sources. Below is the sequence chart of SPI bus data
transmission.
Serial Data Line Buffer
(SPIxRXB)
Shift Register
SPIxSR
SPI Buffer
SPIxBUF
Serial Data Line Buffer
(SPIxRXB)
Shift Register
SPIxSR
Serial Transmission Buffer
(SPIxTXB)
SPI Buffer
SPIxBUF
Serial Transmission Buffer
(SPIxTXB)
Highest Bit Lowest Bit Highest Bit Lowest Bit
SDIx SDOx
SDIxSDOx
Processor 1[SPI Host] Processor 2[SPI Slave]
SCKx
Serial Clock
SCKx
Figure 5-15 SPI Trigger
Trigger Type:
Press Type to open the trigger type list. Rotate and press down to select
“SPI”. At this point, the trigger setting information as shown in the figure below is
displayed at the upper right corner of the screen. For example,
.
The trigger type is SPI trigger; the trigger source is CH1; the trigger level is 0.00 V.
Source Selection:
Press SCL and SDA to specify the data sources of SCL and SDA respectively. They
can be set to CH1, CH2 or any channel of D0-D15. For the details, please refer to the
introduction in “
Trigger Source”. The current trigger source is displayed at the
upper right corner of the screen.
Note: Select channel with signal input as trigger source to obtain stable trigger.