Datasheet
Amplitude
Setting Range
Specication level range Setting range
Maximum output level
[1]
9 kHz ≤ f < 100 kHz +5 dBm
100 kHz ≤ f ≤ 3 GHz +13 dBm +20 dBm
Minimum output level
9 kHz ≤ f ≤ 100 kHz -110 dBm
100 kHz < f ≤ 3 GHz -110 dBm -110 dBm
Setting Resolution 0.01 dB
Absolute Level Uncertainty
Level uncertainty
Temperature range: 20
℃
to 30
℃
+13 dBm to -60 dBm -60 dBm to -110 dBm
100 kHz ≤ f ≤ 3 GHz
≤ 0.9 dB,
≤ 0.5 (typ.)
≤ 1.1 dB,
≤ 0.7 (typ.)
VSWR
[2]
1 MHz ≤ f ≤ 3 GHz < 1.8 (typ.)
Level Setting
Setting time
[3]
Fixed frequency, temperature range: 20
℃
to 30
℃
≤ 5 ms (typ.)
Max. Reverse Power
Max. reverse power
Max. DC voltage 50 V
1 MHz < f ≤ 3 GHz 1 W
Level Sweep
Sweep type
Step sweep (equally spaced level steps)
List sweep (list with arbitrary level steps)
Sweep mode Single, continuous
Sweep range Full level range
Sweep shap
e
Triangle, ramp
Step change Linear
Number of points
Step sweep 2 to 65535
List sweep 1 to 6001
Dwell time 20 ms to 100 s
Trigger mode Auto, key, external, bus (USB, LAN)
Maximum and minimum level vs. frequency Measured maximum level vs.frequency
Note:
[1] Typical maximum output level up to +20 dBm (±1 dB) when output frequency ≥ 10 MHz.
[2] In 50 Ω measurement system, typical value, output level ≤ -10 dBm.
[3] Time from receipt of SCPI command or trigger signal to within 0.1 dB of nal level.