User Manual

DSA800 Series Specifications RIGOL
Page 8/17
Input Attenuation Switching Uncertainty
DSA815
DSA832E
DSA832
DSA875
Setting range
0 to 30 dB, in 1 dB step
Switching uncertainty
f
c
= 50 MHz, relative to 10 dB, 20 to 30
< 0.5 dB
< 0.3 dB
Absolute Amplitude Uncertainty
DSA815
DSA832E
DSA832
DSA875
Uncertainty
f
c
= 50 MHz, peak detector, preamplifier off, attenuation = 10
dB, input signal level = -10 dBm, 20 to 30
<0.4 dB
<0.3 dB
RBW Switching Uncertainty
Uncertainty
relative to 1 kHz RBW
<0.1 dB
Reference Level
Range
-100 dBm to +20 dBm, in 1 dB step
Resolution
log scale
0.01 dB
linear scale
4 digits
Preamplifier
DSA815
(standard)
PA-DSA832E
(option)
PA-DSA832
(option)
PA-DSA875
(option)
Gain
100 kHz to 1.5
GHz
20 dB (nom.)
17 dB (nom.)
17 dB (nom.)
17 dB (nom.)
1.5 GHz to 3.2
GHz
3.2 GHz to 7.5
GHz