User Manual

DSA800 Series Specifications RIGOL
Page 5/17
Displayed Average Noise Level (DANL) (Normalized to 1Hz)
DSA815
DSA832
DSA875
Frequency
attenuation = 0 dB, RBW = VBW = 100 Hz, sample detector,
trace average ≥ 50, tracking generator off, normalized to 1Hz,
20 to 30, input impendence = 50 Ω
PA off
9 kHz to 100 kHz
<-120 dBm (typ.)
<-120 dBm (typ.)
100 kHz to 1 MHz
<-110 dBm,
<-130 dBm (typ.)
<-135 dBm,
<-138 dBm (typ.)
<-135 dBm,
<-138 dBm (typ.)
1 MHz to 5 MHz
<-130 dBm + 6 ×
(f/1 GHz) dB,
<-135 dBm (typ.)
5 MHz to 1.5 GHz
<-140 dBm,
<-144 dBm (typ.)
<-140 dBm,
<-144 dBm (typ.)
1.5 GHz to 3.2 GHz
3.2 GHz to 6 GHz
<-136 dBm,
<-140 dBm (typ.)
6 GHz to 7.5 GHz
<-131 dBm,
<-135 dBm (typ.)
PA on
100 kHz to 1 MHz
<-130 dBm,
<-150 dBm (typ.)
<-152 dBm (typ.)
<-152 dBm (typ.)
1 MHz to 5 MHz
<-150 dBm + 6 ×
(f/1 GHz) dB,
<-155 dBm (typ.)
<-152 dBm,
<-155 dBm (typ.)
<-152 dBm,
<-155 dBm (typ.)
5 MHz to 1.5 GHz
<-157 dBm,
<-161 dBm (typ.)
<-157 dBm,
<-161 dBm (typ.)
1.5 GHz to 3.2 GHz
3.2 GHz to 6 GHz
<-153 dBm,
<-157 dBm (typ.)
6 GHz to 7.5 GHz
<-148 dBm,
<-152 dBm (typ.)