2-42
Power Sweep
Enable or disable the power sweep function.
When enabled, the output power of the TG varies with the sweep rate of the
analyzer within the specified sweep frequency range (from start to stop frequency)
and increases gradually from the specified TG power (see “TG ”) within the
specified power range (see “Power Range”). When disabled, the TG output is
fixed at the specified power (see “TG ”).
Note: this function in not available in zero span mode.
Freq (Hz)
Ampl (dBm)
Start Freq Stop Freq
TG Output
TG Level
Power
Range
Figure 2-12 Power Sweep
Power Range
Set the output power range of the TG in power sweep mode. This parameter
together with the TG level forms the boundary parameters in power sweep mode.
You can use the numeric keys, knob or direction keys to modify this parameter. For