User manual
User’s Guide for DSA800 Series
Chapter 2 Front Panel Operation RIGOL
2-21
Table 2-10 Edit menus of Amplitude correction
Menu
Explanation
Point
Create or edit the data point of a correction factor.
Range: 1 to 200
Frequency
Set the frequency of the specified point in the correction
facor.
Amplitude
Set the amplitude correction of the specified point in the
correction facotr.
Range: -120 dB to 100 dB
Del Point
Delete the specified point data in the correction factor:
frequency and amplitude correction.
4. Freq Interp
Set the interpolation type of the points between two points in the correction
table during amplitude correction.
In Lin mode, the frequency and amplitude separately use a Lin and Log
unit to perform interpolation.
In Log mode, both of the parameters use a Log unit.
5. Delete
Clear the frequency and amplitude correction data of the selected correction
factor.
6. Corr Table
Turn on the correction table to view the correction data edited. At this
moment, the screen is divided into two parts with the upper showing the
measurement curve and the lower showing the points edited, frequency, and
amplitude.
7. Corr View
All: view the data of all the correction factors.
Sel: view the data of the selected correction factor.