User manual

RIGOL Chapter 2 Front Panel Operation
User’s Guide for DSA800 Series
2-90
Peak
Open the peak search setting menu and execute peak search.
Key Points:
If Max is selected in Search Para Peak Search, the system will search
and mark the maximum on the trace.
If Param is selected in Search Para Peak Search, the system will search
and mark the peak that meets the peak search condition.
The search of Next Peak, Peak Right, Peak Left or peaks in the peak table
must meet the specified peak search condition.
The spurious signal caused by LO feed through at zero frequency is ignored.
When no peak that meets the specified peak search condition is found, No
peak found is displayed.
Next Peak
Search and mark the peak whose amplitude is closest to that of the current peak
and which meets the peak search condition.
Peak Right
Search and mark the nearest peak which is located at the right side of the current
peak and meets the peak search condition.
Peak Left
Search and mark the nearest peak which is located at the left side of the current
peak and meets the peak search condition.