User Manual
Chapter 5 Specifications  RIGOL 
User’s Guide for DSA800 Series   
5-13 
Electromagnetic Compatibility and Safety 
EMC 
in line with EN61326-1:2006 
IEC 61000-4-2:2001  ±4.0 kV (contact discharge), ±4.0 kV (air discharge) 
IEC 61000-4-3:2002 
3 V/m (80 MHz to 1 GHz), 3 V/m (1.4 GHz to 2 GHz), 
1 V/m (2.0 GHz to 2.7 GHz) 
IEC 61000-4-4:2004  1 kV power lines 
IEC 61000-4-5:2001 
0.5 kV (phase to neutral), 0.5 kV (phase to PE), 1 kV 
(neutral to PE) 
IEC 61000-4-6:2003  3 V, 0.15 to 80 MHz 
IEC 
61000-4-11:2004 
voltage dip: 0% UT during half cycle, 0% UT during 1 
cycle, 70% UT during 25 cycles 
short interruption: 0% UT during 250 cycles 
Electrical safety 
in line with 
UL 61010-1:2012, CAN/CSA-C22.2 No. 61010-1-12, 
EN 61010-1:2010 
Dimensions 
(W × H × D) 
361.6 mm × 178.8 mm × 128 mm 
(14.2 in × 7.0 in × 5.0 in)  
Weight   
  DSA815  DSA832  DSA875 
Standard 
4.25 kg (9.4 lb) 
4.55 kg (10.0 lb) 
With tracking generator  5.15 kg (11.4 lb) 