Instructions
Chapter 2 Command System  RIGOL 
MSO7000/DS7000 Programming Guide  2-115   
:MEASure:AREA 
Syntax 
:MEASure:AREA <area> 
:MEASure:AREA? 
Description 
Sets or queries the type of the measurement range. 
Parameter 
Name 
Type 
Range 
Default 
<area> 
Discrete 
{MAIN|ZOOM|CURSor} 
MAIN 
Remarks 
  MAIN: indicates that the measurement range is within the main time base region.   
  ZOOM: indicates that the measurement range is within the zoomed time base 
region. Note that only when you enable the delayed sweep function first, can 
"Zoom" be enabled. 
  CURSor: when you select it, two cursor lines will be displayed on the screen. 
Return 
Format 
The query returns MAIN, ZOOM, or CURS. 
Example 
:MEASure:AREA ZOOM /*Sets the type of the measurement range to ZOOM.*/ 
:MEASure:AREA?                    /*The query returns ZOOM.*/ 
:MEASure:CREGion:CAX 
Syntax 
:MEASure:CREGion:CAX <cax> 
:MEASure:CREGion:CAX? 
Description 
Sets or queries the position of Cursor A when the measurement range is the "cursor 
region". 
Parameter 
Name 
Type 
Range 
Default 
<cax> 
Integer 
0 to 1,000 
600 
Remarks 
  The position of the cursor is defined by the pixel coordinate of the screen. The 
range of the pixel coordinate on the screen horizontally is from 0 to 1,000 (from 
left to right). 
  You can run the :MEASure:AREA command to set the measurement range to 
"cursor region". 
Return 
Format 
The query returns the position of Cursor A in integer. 
Example 
:MEASure:CREGion:CAX 100                            /*Sets the position of Cursor A to 100.*/ 
:MEASure:CREGion:CAX?                                  /*The query returns 100.*/ 