Instructions
Chapter 2 Command System  RIGOL 
MSO7000/DS7000 Programming Guide  2-91   
:MASK:OPERate 
Syntax 
:MASK:OPERate <oper> 
:MASK:OPERate? 
Description 
Runs or stops the pass/fail test; or queries the operating status of the pass/fail test. 
Parameter 
Name 
Type 
Range 
Default 
<oper> 
Discrete 
{RUN|STOP} 
STOP 
Description 
Before running this command, send the :MASK:ENABle command to enable the pass/fail 
test function. 
Return 
Format 
The query returns RUN or STOP. 
Example 
:MASK:OPERate RUN        /*Runs the pass/fail test function.*/ 
:MASK:OPERate?                /*The query returns RUN.*/ 
:MASK:MDISplay 
Syntax 
:MASK:MDISplay <bool> 
:MASK:MDISplay? 
Description 
Enables or disables the statistical function; or queries the on/off status of the statistical 
function when the pass/fail test is enabled. 
Parameter 
Name 
Type 
Range 
Default 
<bool> 
Bool 
{{1|ON}|{0|OFF}} 
0|OFF 
Description 
  Before running this command, send the :MASK:ENABle command to enable the 
pass/fail test function. 
  When the statistics is enabled, the following test results are displayed on the 
screen, as shown in the figure below. 
Return 
Format 
The query returns 1 or 0. 
Example 
:MASK:MDISplay ON /*Enables the statistics.*/ 
:MASK:MDISplay?            /*The query returns 1.*/ 