Instructions
RIGOL  Chapter 5 To Trigger the Oscilloscope 
5-10  MSO7000/DS7000 User's Guide 
Please refer to descriptions in "Trigger LEVEL/Threshold Level". The current 
trigger level/threshold level value is displayed at the upper-right corner of the screen. 
Pulse Trigger 
Triggers on the positive or negative pulse with a specified width. In this mode, the 
oscilloscope will trigger when the pulse width of the input signal satisfies the 
specified pulse width condition. 
In this oscilloscope, positive pulse width is defined as the time difference between 
the two crossing points of the trigger level and positive pulse; negative pulse width is 
defined as the time difference between the two crossing points of the trigger level 
and negative pulse, as shown in the figure below. 
Figure 5-3 Positive Pulse Width/Negative Pulse Width 
Trigger Type: 
Press Type, and then rotate the multifunction knob    to select "Pulse". Press 
down the knob to select the trigger type. Then, the current trigger setting 
information is displayed at the upper-right corner of the screen, as shown in the 
figure below. You can also press the Type key continuously or enable the touch 
screen to select the desired trigger type. 
Source Selection: 
Press  Source  to  open  the  signal  source  list  and  select  CH1-CH4  or  D0-D15.  For 
details,  refer  to  descriptions  in  "Trigger  Source".  The  current  trigger  source  is 
displayed at the upper-right corner of the screen. 
Note: Only when we select the channel (that has been input with signals) as the 
trigger source, can we obtain a stable trigger. 
Trigger 
Level 
Trigger 
Level 
+Width 
A 
B 
-Width 
A 
B 