Instructions
Chapter 16 Display Control    RIGOL 
MSO7000/DS7000 User's Guide  16-3 
To Set the Waveform Intensity 
Press Intensity, then rotate the multifunction knob    at a small step value or use 
the pop-up numeric keypad to set the waveform intensity. Note that in the non-menu 
operation  mode,  you  can  also  rotate  the multifunction  knob    to  adjust  the 
waveform brightness of the channel. The default is 60%, and the range available is 
from 1% to 100%. 
To Set the Screen Grid 
Press Grid, and rotate the multifunction knob    to set the grid type and then press 
down the knob to select it. You can also press Grid continuously or enable the touch 
screen to select it. You can select "FULL", "HALF", "NONE", or "IRE". 
  FULL: turns the background grid and coordinate on. 
  HALF: turns the background grid off. 
  NONE: turns the background grid and coordinate off. 
  IRE: only available for testing the video signal (i.g. the trigger type is set to       
"Video" trigger, and the vertical offset is set to 140 mV). 
To Set the Grid Brightness 
Press Brightness, then rotate the multifunction knob    at a small step value or 
use the pop-up numeric keypad to set the grid intensity. The default is 20%, and the 
range available is from 1% to 100%. 
Scale 
Press Show Scale continuously to enable or disable the scale display on the screen. 
By default, it is set to "OFF". 
Note: When the digital channel is enabled, the scale in the vertical direction is 
hidden automatically. 
Color Grade 
Press More  Color Grade to enable or disable the color grade display of the 
analog channel waveforms on the screen. By default, it is set to "OFF". When 
enabled, different colors are displayed on the screen to indicate the times of data 