Instructions
RIGOL  Chapter 11 Protocol Decoding 
11-2  MSO7000/DS7000 User's Guide 
Parallel Decoding 
Parallel bus consists of clock line and data line. As shown in the figure below, CLK is 
the clock line, whereas Bit0 and Bit1 are the 0 bit and 1st bit on the data line 
respectively. The oscilloscope will sample the channel data on the rising edge, falling 
edge, or the rising/falling edge of the clock and judge each data point (logic "1" or 
logic "0") according to the preset threshold level. 
Figure 11-1 Schematic Diagram of Parallel Decoding 
In the decode setting menu, press Decode1  Bus Type, then rotate the 
multifunction knob    to select "Parallel". Press down the knob to select it. 
You can also press Bus Type continuously or enable the touch screen to select it. 
1. Enable or disable the bus 
Press Bus Status to enable or disable the decoding function. 
2. Clock setting (CLK) 
Press Clock to enter the clock line setting menu. 
  Set clock channel 
Press Clock, then rotate the multifunction knob    to select any clock 
channel. Press down the knob to select it. You can also press Clock 
continuously or enable the touch screen to select it. The analog channel 
(CH1-CH4) and digital channel (D0-D15) can all be selected as the clock 
source. If "OFF" is selected, no clock channel is set, and sampling is 
performed when a hop occurs to the data of the data channel during 
decoding. 
  Set the clock edge type 
Press CLK Edge, then rotate the multifunction knob    to select the clock 
edge type. Press down the knob to select it. You can also press CLK Edge 
continuously or enable the touch screen to select it. You can select to 
sample the channel data on the rising edge ( ), falling edge ( ), or 
both edges ( ) of the clock signal. 
Rising : samples the channel data on the rising edge of the clock. 