Instructions
RIGOL  Chapter 8 Power Analysis (Option) 
8-2  MSO7000/DS7000 User's Guide 
Power Quality   
By analyzing the power quality, you can test the quality of AC input lines. The specific 
measurement parameters for power quality analysis include V_RMS, I_RMS, real 
power, apparent power, reactive power, power factor, reference frequency, phase 
angle, impedance, voltage crest factor, and current crest factor. 
Press Measure  Analyze  Power Analyzer to open the power analysis setting 
menu, or enable the touch screen and then tap the function navigation icon    at 
the lower-left corner of the screen to open the function navigation. Then, tap the 
"Power" icon to open the power analysis setting menu. 
  Select the Analysis Type 
In the power analysis setting menu, press Analysis Type and rotate the 
multifunction knob    to select "Power Quality", and then press down the knob 
to select it. You can also press Analysis Type continuously or enable the touch 
screen to select the desired analysis type. 
  Set the Power Quality Analysis Source 
In the power analysis setting menu, press Source to enter the source setting 
menu. 
  Press Voltage and then rotate the multifunction knob    to select the 
channel (CH1-CH4) for acquiring voltage. Press down the knob to select it. 
You can also press Voltage continuously or enable the touch screen to 
select the channel. 
  Press Current and then rotate the multifunction knob    to select the 
channel (CH1-CH4) for acquiring current. Press down the knob to select it. 
You can also press Current continuously or enable the touch screen to 
select the channel. 
  Press Freq. Ref continuously to select "Voltage" or "Current" as the 
frequency reference. 
  Set the Reference Level 
In the power analysis setting menu, press Ref Levels (level of the frequency 
reference channel) to enter the reference level setting menu. 
  Press Type, and rotate the multifunction knob    to set the reference 
level display type to "Percent(%)" or "Absolute", and then press down the 
knob to select it. You can also press Type continuously or enable the touch 
screen to select the type. 
  Press Upper, then rotate the multifunction knob    or use the pop-up 
numeric keypad to set the upper limit value. Reducing the upper limit to the 
current middle value will automatically reduce the middle value and lower 
limit to keep them lower than the upper limit. 
  Press Mid, then rotate the multifunction knob    or use the pop-up 
numeric keypad to set the middle value. The middle value is limited by the 