Specifications
RIGOL 2 Command System
2-160 MSO2000A/DS2000A Programming Guide
:MEASure:F2RPhase:SMAXimum
:MEASure:F2RPhase:SMINimum
:MEASure:F2RPhase:SCURrent
:MEASure:F2RPhase:SAVerage
:MEASure:F2RPhase:SDEViation
Syntax 1
:MEASure:F2RPhase:SMAXimum <chanA>,<chanB>
:MEASure:F2RPhase:SMINimum <chanA>,<chanB>
:MEASure:F2RPhase:SCURrent <chanA>,<chanB>
:MEASure:F2RPhase:SAVerage <chanA>,<chanB>
:MEASure:F2RPhase:SDEViation <chanA>,<chanB>
Description 1
Enable the phase deviation (falling edge-rising edge) measurement function between the two specified
channels and the statistic function of the measurement results.
Syntax 2
:MEASure:F2RPhase:SMAXimum? <chanA>,<chanB>
:MEASure:F2RPhase:SMINimum? <chanA>,<chanB>
:MEASure:F2RPhase:SCURrent? <chanA>,<chanB>
:MEASure:F2RPhase:SAVerage? <chanA>,<chanB>
:MEASure:F2RPhase:SDEViation? <chanA>,<chanB>
Description 2
Query the statistic maximum value, minimum value, current value, average value or standard deviation of
the phase deviation (falling edge-rising edge) measurement results when the phase deviation (falling
edge-rising edge) measurement function between the two specified channels and the statistic function of
the measurement results are enabled.
Parameter
Name Type Range Default
<chanA> Discrete
{D0|D1|D2|D3|D4|D5|D6|D7|D8|D9|D10|D11|
D12|D13|D14|D15|CHANnel1|CHANnel2}
--
<chanB> Discrete
When <chanA> is D0-D15:
{D0|D1|D2|D3|D4|D5|D6|D7|D8|D9|D10|D11|
D12|D13|D14|D15}
When <chanA> is CHANnel1 or CHANnel2:
{CHANnel1|CHANnel2}
--
Return Format
The query returns the statistic maximum value, minimum value, current value, average value or standard
deviation of the phase deviation (falling edge-rising edge) measurement results in scientific notation.
When the measurement results are invalid, the query returns 9.9e37.