Specifications
2 Command System RIGOL
MSO2000A/DS2000A Programming Guide
2-149
:MEASure:SETup:PSA
:MEASure:SETup:PSB
Syntax
:MEASure:SETup:PSA <sourceA>
:MEASure:SETup:PSA?
:MEASure:SETup:PSB <sourceB>
:MEASure:SETup:PSB?
Description
Set or query the channel source of source A or B in phase deviation measurements.
Parameter
Name Type Range Default
<sourceA> Discrete
{D0|D1|D2|D3|D4|D5|D6|D7|D8|D9|D10|D11|D12|
D13|D14|D15|CHANnel1|CHANnel2}
CHANnel1
<sourceB> Discrete
When <sourceA> is D0-D15:
{D0|D1|D2|D3|D4|D5|D6|D7|D8|D9|D10|D11|D12|
D13|D14|D15}
When <sourceA> is CHANnel1 or CHANnel2:
{CHANnel1|CHANnel2}
CHANnel2
Explanation
You can use the phase deviation measurement function to measure 4 kinds of phase deviations between
tow channels: source A rising edge-source B rising edge (
:MEASure:RPHase), source A rising edge-source
B falling edge (
:MEASure:R2FPhase), source A falling edge-source B falling edge (:MEASure:FPHase) and
source A falling edge-source B rising edge (
:MEASure:F2RPhase).
Return Format
The query returns D0, D1, D2, D3, D4, D5, D6, D7, D8, D9, D10, D11, D12, D13, D14, D15, CHAN1 or
CHAN2.