Specifications
2 Command System RIGOL
DS2000 Programming Guide
2-551
:WAVeform:POINts
Syntax
:WAVeform:POINts <point>
:WAVeform:POINts?
Description
Set the number of waveform points to be read.
Query the current number of waveform points to be read.
Parameter
Name Type Range Default
<point> Integer
NORMal: 1 to 1400
MAX: 1 to the number of effective
points currently on the screen
RAW: 1 to the current maximum
memory depth
--
Explanation
The number of waveform points is limited by the current reading mode of waveform
(refer to the
:WAVeform:MODE command).
Return Format
The query returns an integer.
Example
:WAVeform:POINts 600