:TRIGger:RS232:STOP
Syntax
:TRIGger:RS232:STOP <bit>
:TRIGger:RS232:STOP?
Description
Set the stop bit in RS232 trigger when the trigger condition is Error.
Query the current stop bit in RS232 trigger when the trigger condition is Error.
Parameter
Name Type Range Default
<bit> Discrete {1|2} 1
Explanation
To set the trigger condition, refer to the
:TRIGger:RS232:WHEN command.
Return Format
The query returns 1 or 2.
Example
:TRIGger:RS232:STOP 2