Specifications

RIGOL 2 Command System
2-508 DS2000 Programming Guide
2-508
:TRIGger:SHOLd:TYPe
Syntax
:TRIGger:SHOLd:TYPe <type>
:TRIGger:SHOLd:TYPe?
Description
Set the hold type of setup/hold trigger.
Query the current hold type of setup/hold trigger.
Parameter
Name Type Range Default
<type> Discrete {SETup|HOLd|SETHOLd} SETup
Explanation
SETup: set the time (refer to the
:TRIGger:SHOLd:STIMe command) that the data
stays stable and constant before the clock edge appears.
HOLd: set the time (refer to the
:TRIGger:SHOLd:HTIMe command) that the data
stays stable and constant after the clock edge appears.
SETHOLd: set the time (refer to the
:TRIGger:SHOLd:STIMe
and
:TRIGger:SHOLd:HTIMe commands) that the data stays stable and constant
before and after the clock edge appears.
Return Format
The query returns SETup, HOL or SETHOL.
Example
:TRIGger:SHOLd:TYPe SETHOLd
The query returns SETHOL.