Specifications
RIGOL 2 Command System
2-478 DS2000 Programming Guide
2-478
:TRIGger:VIDeo:LINE
Syntax
:TRIGger:VIDeo:LINE <line>
:TRIGger:VIDeo:LINE?
Description
Set the line number in video trigger when the sync type is Line Number (refer to
the
:TRIGger:VIDeo:MODE command).
Query the current line number of the specified line.
Parameter
Name Type Range Default
<line> Integer
NTSC:1 to 525
PAL:1 to 625
480P:1 to 525
576P:1 to 625
720P60HZ:1 to 750
720P50HZ:1 to 750
720P30HZ:1 to 750
720P25HZ:1 to 750
720P24HZ:1 to 750
1080P60HZ:1 to 1125
1080P50HZ:1 to 1125
1080P30HZ:1 to 1125
1080P25HZ:1 to 1125
1080P24HZ:1 to 1125
1080I30HZ:1 to 1125
1080I25HZ:1 to 1125
1080I24HZ:1 to 1125
1
Return Format
The query returns an integer.
Example
:TRIGger:VIDeo:LINE 100
The query returns 100.