:TRIGger:SLOPe:WHEN
Syntax
:TRIGger:SLOPe:WHEN <when>
:TRIGger:SLOPe:WHEN?
Description
Select the trigger condition of slope trigger.
Query the current trigger condition of slope trigger.
Parameter
Name Type Range Default
<when> Discrete
{PGReater|PLESs|NGReater|NLESs|PG
Less|NGLess}
PGReater
Explanation
PGReater: you need to specify a time value (refer to the
:TRIGger:SLOPe:TLOWer
command). The oscilloscope triggers when the positive slope time of the input signal
is greater than the specified time.
PLESs: you need to specify a time value (refer to the
:TRIGger:SLOPe:TUPPer
command). The oscilloscope triggers when the positive slope time of the input signal
is lower than the specified time.
NGReater: you need to specify a time value (refer to the
:TRIGger:SLOPe:TLOWer
command). The oscilloscope triggers when the negative slope time of the input
signal is greater than the specified time.
NLESs: you need to specify a time value (refer to the
:TRIGger:SLOPe:TUPPer
command). The oscilloscope triggers when the negative slope time of the input
signal is lower than the specified time.
PGLess: you need to specify an upper limit (refer to the
:TRIGger:SLOPe:TUPPer
command) and a lower limit (refer to the
:TRIGger:SLOPe:TLOWer command) of
time. The oscilloscope triggers when the positive slope time of the input signal is
greater than the specified lower limit and lower than the specified upper limit.
NGLess: you need to specify an upper limit (refer to the
:TRIGger:SLOPe:TUPPer
command) and a lower limit (refer to the
:TRIGger:SLOPe:TLOWercommand) of
time. The oscilloscope triggers when the negative slope time of the input signal is
greater than the specified lower limit and lower than the specified upper limit.