Specifications

2 Command System RIGOL
DS2000 Programming Guide
2-443
:TRIGger:PULSe:UWIDth
Syntax
:TRIGger:PULSe:UWIDth <width>
:TRIGger:PULSe:UWIDth?
Description
Set the upper limit of the pulse width in pulse trigger and the unit is s.
Query the current upper limit of the pulse width in pulse trigger.
Parameter
Name Type Range Default
<width> Real 2ns to 4s 2μs
Note: when the trigger condition is PGLess or NGLess, the range is from 10ns to 4s.
Explanation
This command is available when the trigger condition (refer to
the
:TRIGger:PULSe:WHEN command) is PLESs, NLESs, PGLess or NGLess.
Return Format
The query returns the upper limit of the pulse width in scientific notation.
Example
:TRIGger:PULSe:UWIDth 0.000003
The query returns 3.000000e-06.