Quick Guide RIGOL Publication number QGA04114-1110 Feb. 2014 DS1000B Series Digital Oscilloscope DS1074B, DS1104B, DS1204B © 2008 RIGOL Technologies, Inc.
RIGOL ENGLISH Copyright © 2008 RIGOL Technologies, Inc. All Rights Reserved. RIGOL products are protected by patent laws in and outside of the P.R. China. Information in this publication replaces all previous corresponding material. RIGOL reserves the right to modify or change part of or all the specifications and pricing policies at company’s sole decision. NOTE: RIGOL is registered trademark of RIGOL Technologies, Inc. © 2008 RIGOL Technologies, Inc.
RIGOL ENGLISH Safety Notice Review the following safety precautions carefully to avoid any personal injuries or damages to the instrument and any products connected to it. To avoid potential hazards, please use the instrument as specified by this manual only. The instrument should be serviced by Authorized personnel only. To Avoid Fire or Personal Injury. Use Proper Power Cord. Use the power cord designed for the instrument and authorized in your country only. Ground The Instrument.
RIGOL Provide Proper Ventilation. Refer to the installation instructions for proper ventilation of the instrument. Do not Operate in Wet/Damp Conditions. Do not Operate in an Explosive Atmosphere. Keep Product Surfaces Clean and Dry. The disturbance test of all the models meet the limit values of A in the standard of EN 61326: 1997+A1+A2+A3, but can’t meet the limit values of B. Measurement Category The DS1000B series Digital Oscilloscope is intended to be used for measurements in Measurement Category I.
RIGOL ENGLISH Safety Terms and Symbols Terms in This Guide. These terms may appear in this manual: ! ! WARNING: Warning statements indicate the conditions or practices that could result in injury or loss of life. CAUTION: Caution statements indicate the conditions or practices that could result in damage to this product or other property. Terms on the Product. These terms may appear on the product: DANGER indicates an injury or hazard that may be immediately happen.
RIGOL ENGLISH Contents Necessary Inspection 1 How to Connect Power Cord 4 How to Connect Probe or BNC 5 How to Connect USB Devices 7 Troubleshooting 8 Contact RIGOL 10 © 2008 RIGOL Technologies, Inc.
RIGOL ENGLISH Necessary Inspection 1. Inspect the shipping container for damage. Keep the damaged shipping container or cushioning material until the contents of the shipment have been checked for completeness and the instrument has been checked mechanically and electrically. 2. Inspect the instrument. In case there is any mechanical damage or defect, notify the RIGOL Sales Representative.
RIGOL ENGLISH I. Front Panel of the instrument DS1000B Series Front Panel II. Standard accessory 2 A Power Cord Four Passive Probes A USB Cable A CD-ROM* © 2008 RIGOL Technologies, Inc.
RIGOL ENGLISH A Quick Guide A Warranty Card NOTE*: The CD-ROM includes《User’s Guide》and Application Software. III. Optional accessories BNC Cable USB-GPIB Adapter Instrument Carrying Case © 2008 RIGOL Technologies, Inc.
RIGOL ENGLISH How to Connect Power Cord After inspecting the instrument and the accessories, connect the power cord as shown in the following figure. Turn on the switch which is under the power socket, the instrument then is powered on, and the power key on the front pannel is lit up (twinkle like breathing),press the key to start up the instrumemt.
RIGOL ENGLISH How to Connect Probe or BNC 1. Connect the probe As shown in the above figures, set the attenuation switch on the probe to 10X and connect the probe to Channel 1 on the oscilloscope, push and rotate clockwise to lock the probe in place. If your probe is a new one, or if it is the first time you connect to the oscilloscope, before use it, please do the following compensation operation: © 2008 RIGOL Technologies, Inc.
RIGOL ENGLISH (1) Set the attenuation switch on the probe to 10X and connect the probe to Channel 1 on the oscilloscope. Attach the probe tip and ground lead to the PROBE COMP connector. Press CH1, and set the attenuation menu to 10X. Then press AUTO.
RIGOL ENGLISH How to Connect USB Devices DS1000B series oscilloscope support the USB flash drive and connections to PC or printer throught USB. The instrument provides two USB Hosts and a USB Device. Connect USB Host (Front Panel) Connect USB Host (Rear Panel) Connect USB Device(Rear Panel) © 2008 RIGOL Technologies, Inc.
RIGOL ENGLISH Troubleshooting 1. (1) (2) (3) (4) 2. (1) (2) (3) (4) (5) After the oscilloscopes is powered on, the screen remains dark (no display): Check the power cord connection. Ensure the power switch is turned on. After the above inspection, restart the oscilloscope. If the problem still remains, please contact RIGOL for help. After the signal acquisition the waveform does not appear: Check the probes connected with the signals. Check the probes connected to the channels firmly.
RIGOL After pressing the RUN/STOP button, the oscilloscope does not display any waveform on screen. Check whether the Trigger Mode is set to “Normal” or “Single” and see whether the trigger level is out of the signal range. If yes, set the trigger level in proper range by turning knob or pressing the 50% button. Or set the the Trigger Mode as “AUTO”. Moreover, push AUTO button to display the waveform on screen. 6.
RIGOL ENGLISH Contact RIGOL If you have any problem or requirement when using our products or this manual, please contact RIGOL. E-mail: service@rigol.com Website: www.rigol.com 10 © 2008 RIGOL Technologies, Inc.