RIGOL Chapter 6 To Make Measurements
DS1000Z Users Guide
5-20
Duration Trigger
Identify a trigger condition by looking for the duration of a specified pattern. This
pattern is a logical ANDcombination of the four channels. Each channel can have a
value of high (H), low (L) or dont care (X). The instrument triggers when the
duration (T) of this pattern meets the preset time, as shown in the figure below.
Figure 5-7 Duration Trigger Schematic Diagram
Trigger Type:
Press Type to select Duration. At this point, the trigger setting information as
shown in the figure below is displayed at the upper right corner of the screen.
Source Selection:
Press Source to select CH1-CH4 respectively. The current signal source is displayed
at the upper right corner of the screen.