User`s guide

Chapter 7 Protocol Decoding RIGOL
DS1000Z Users Guide
7-5
width.
Press DataSrc to select Traceor Memoryas the data source.
Dig. Sa displays the current digital sample rate. The digital sample rate is
related to the data source currently selected. When the data source is set to
Trace, the digital sample rate is related to the horizontal time base; when
the data source is set to Memory, the digital sample rate is related to the
sample rate and memory depth.
11. Event Table
The event table displays the decoded data and the corresponding line number
and time in table form. It can be used to observe relatively longer decoded data
to solve the problem that some data cannot be viewed cleared on the screen.
Press Evt.Table EventTable and select “ON” (note: this operation is only
available when Decode is set to “ON”) to enter the event table interface as
shown in
Figure 7-2.
Format: set the display format of the “Data” in the event table to HEX, DEC or
ASC.
Focus: rotate
to select the desired data.
View: set the display format of the vent table to packets, details or payload.
Data: select the data column to be viwed in the “Details” or “Payload” views.
Order: set the display type of the decoding results in the event table to ascend
or descend.
Export: if an USB storage device is currently connected to the instrument, you
can press Export to export the data table to the external USB storage device in
CSV format.