Datasheet
Temperature Coefficient per℃ (Output Percentage + Offset)
Voltage
Current
Stability
[3]
±(Output Percentage + Offset)
Voltage
Current
Voltage Programming Control Speed (1% within the total variation range)
Rise
Fall
OVP/OCP
Accuracy ±(Output
Percentage + Offset)
Activation Time
Mechanical
Dimensions
Weight
Power
AC Input
(50Hz to 60Hz)
I/O
USB Device
USB Host
LAN
RS232
Digital IO
USB-GPIB
Environment
Working Temperature
Cooling Method
Model
Channels
DC Output (0℃ to 40℃)
Voltage
Current
OVP
OCP
Load Regulation Rate ±(Output Percentage + Offset)
Voltage
Current
Linear Regulation Rate ±(Output Percentage + Offset)
Voltage
Current
Ripples and Noise (20Hz to 20MHz)
Normal Mode Voltage
Normal Mode Current
Note:
[1] The accuracy parameters are acquired via calibration under 25℃ after 1-hour warm-up.
[2] The maximum time required for the output to change accordingly after receiving the APPLy and SOURce commands.
[3] The variation of the output within 8 hours after 30-minute warm-up when the load circuit and environment temperature are constant.
0~+8V
0~10A
0.1V~8.8V
0.1A~10.5A
0.01%+3mV
0.02%+3mA
0.02% + 1mV
0.1% + 1mA
< 45 ms
< 42 ms
<51ms
<1089ms
0.5%+0.5V/0.5%+0.5A
1.5ms(OVP≥ 3V)
<10ms(OVP<3V和OCP)
239mm(W) x 157mm(H) x 418mm(D)
10.3kg
100Vac+10%,115Vac+10%,230Vac+10%(maximum 250VAC)
1
1
1
1
1
Option
Full Rated Value Output: 0℃ to 40℃
Under Relatively Higher Temperature: the output current decreases linearly to 50% at the highest
temperature 55℃
Fan Cooling
Full Load
No Load
Full Load
No Load
0~+60V
0~1A
0.1V~66V
0.1A~1.1A
60V/1A
DP821A
2
8V/10A
DP821A Specications
<0.01%+2mV
<0.01%+250μA
<0.01%+2mV
<0.01%+250μA
<350μVrms/2mVpp
<2mArms
Transient Response Time
Less than 50μs for output to recover to within 15mV following a change in output current from full load to half load or vice versa.
Command Processing Time
[2]
<100ms