User manual
Chapter 2 Command System RIGOL
DP700 Programming Guide 2-39
Parameter
Name
Type
Range
Default
<state> Bool {ON|OFF} OFF
Remarks
Trigger input indicates that the external trigger input signal controls the on/off state of the channel
output. Pin 8 of the RS232 interface on the rear panel is used to receive the external trigger input
signal. When it receives a high level signal (≥ 2.1 V, 10 mA), the channel output will be turned on;
when it receives a low level signal (≤0.7 V, 10 mA), the channel output will be turned off.
Trigger (including the trigger input and output) is an optional function. If you want to use the function,
order the trigger option (with the order No. TRIGGER-DP700) first, and then install the option
according to the instructions in the
:LIC:SET command.
When multiple power supplies are in serial or parallel connection, using the external trigger function
can realize the synchronous output for multiple power supplies.
Return Format
ON or OFF
Related Command
:SYSTem:TRIGger:OUT[:STATe]
:SYSTem:TRIGger:OUT[:STATe]
Syntax
:SYSTem:TRIGger:OUT[:STATe] <state>
:SYSTem:TRIGger:OUT[:STATe]?
Description
Turns on or off the trigger output.
Queries the on/off status of the trigger output.
Parameter
Name
Type
Range
Default
<state>
Bool
{ON|OFF}
OFF
Remarks
Trigger output indicates that controlling the on/off state of the channel output can enable the
instrument to output the specified signal. Pin 7 of the RS232 interface on the rear panel is used to
output the trigger output signals. When the channel output is turned on, the high level signal (≥2.1 V,
10 mA) is output from Pin 7; when off, the low level signal (≤0.7 V, 10 mA) is output from Pin 7.
Trigger (including the trigger input and output) is an optional function. If you want to use the function,
order the trigger option (with the order No. TRIGGER-DP700) first, and then install the option
according to the instructions in the
:LIC:SET command.
When multiple power supplies are in serial or parallel connection, using the external trigger function
can realize the synchronous output for multiple power supplies.
Return Format
ON or OFF
Related Command
:SYSTem:TRIGger:IN[:STATe]