User manual

RIGOL Chapter 2 Command System
2-26 DP700 Programming Guide
Example
:VOLTage 20 /*Sets the channel output voltage to 20 V*/
:VOLTage? /*Queries the channel voltage setting value*/
Return Format
A real number
Related Command
:APPLy
[:SOURce[<n>]]:VOLTage:PROTection:CLEar
Syntax
[:SOURce[<n>]]:VOLTage:PROTection:CLEar
Description
Clears the internal OVP flag and the OVP prompt message.
Parameter
Name Type Range Default
<n> Discrete {1} 1
Remarks
Before executing the command, ensure that you have located and resolved the problem for causing
the overvoltage protection. To resolve the problem, reduce the output voltage to below the
overvoltage protection value or increase the overvoltage protection value to above the output voltage.
Executing the command will clear the internal OVP flag and the OVP prompt message.
You can send the
:OUTPut:OVP:CLEAR command to clear the internal OVP flag and the OVP prompt
message.
You can also send the
:OUTPut:OVP:ALAR?, :OUTPut:OVP:QUES?, or
[:SOURce[<n>]]:VOLTage:PROTection:TRIPped? command to query whether the overvoltage
protection has currently occurred.
Example
:VOLTage:PROTection:CLEar /*Clears the internal OVP flag and the OVP prompt message*/
Related Commands
:OUTPut:OVP:CLEAR
:OUTPut:OVP:ALAR?
:OUTPut:OVP:QUES?
[:SOURce[<n>]]:VOLTage:PROTection:TRIPped?
[:SOURce[<n>]]:VOLTage:PROTection[:LEVel]
Syntax
[:SOURce[<n>]]:VOLTage:PROTection[:LEVel] {<value>|MINimum|MAXimum}
[:SOURce[<n>]]:VOLTage:PROTection[:LEVel]? [MINimum|MAXimum]
Description
Sets the channel overvoltage protection (OVP) value.
Queries the channel overvoltage protection (OVP) value.