User manual
Chapter 2 Front Panel Operations RIGOL
DP700 User’s Guide 2-3
For setting methods, refer to the descriptions of the help information
displayed at the bottom of the corresponding interface or refer to the
descriptions in "Parameter Setting Method".
Set the output current
(1) In the main interface, press the Up/Down arrow key to switch the
parameter focus to "Current Setting Value".
(2) Use the num key or the knob to set a desired value for the output current.
For setting methods, refer to the descriptions of the help information
displayed at the bottom of the corresponding interface or refer to the
descriptions in "Parameter Setting Method".
Set the overvoltage protection
(1) In the main interface, press the Up/Down arrow key to switch the
parameter focus to "OVP Setting".
(2) Press OK to enable/disable the overvoltage protection function.
When "OVP" is indicated in yellow, it indicates that the overvoltage
protection function is enabled; when "OVP" is indicated in white, it indicates
that the overvoltage protection function is disabled.
(3) Use the num key or the knob to set a desired value for the overvoltage
protection. For setting methods, refer to the descriptions of the help
information displayed at the bottom of the corresponding interface or refer
to the descriptions in "Parameter Setting Method".
Set the overcurrent protection
(1) In the main interface, press the Up/Down arrow key to switch the
parameter focus to "OCP Setting".
(2) Press OK to enable/disable the overcurrent protection function.
When "OCP" is indicated in yellow, it indicates that the overcurrent
protection function is enabled; when "OCP" is indicated in white, it indicates
that the overcurrent protection function is disabled.
(3) Use the num key or the knob to set a desired value for the overcurrent
protection. For setting methods, refer to the descriptions of the help
information displayed at the bottom of the corresponding interface or refer
to the descriptions in "Parameter Setting Method".
4. Turn on the channel output
Press On/Off to turn on the channel output. Then, the actual output voltage
(V), the actual output current (A), and the actual output power (W) are
highlighted; the actual output mode (CV) is displayed.
If the CC mode is displayed, please increase the current setting value
appropriately.