RIGOL English Quick Guide 中文 DP700 Series Programmable Linear DC Power Supply Mar. 2016 RIGOL TECHNOLOGIES, INC.
RIGOL Guaranty and Declaration English Copyright © 2016 RIGOL TECHNOLOGIES, INC. All Rights Reserved. Trademark Information RIGOL is a registered trademark of RIGOL TECHNOLOGIES, INC. Publication Number QGH05101-1110 Notices RIGOL products are covered by P.R.C. and foreign patents, issued and pending. RIGOL reserves the right to modify or change parts of or all the specifications and pricing policies at the company’s sole decision.
RIGOL English General Safety Summary 1. 2. 3. 4. 5. 6. 7. Only the exclusive power cord designed for the instrument and authorized for use within the local country could be used. Ensure that the instrument is safely grounded. Observe all terminal ratings. Use proper overvoltage protection. Do not operate without covers. Do not insert objects into the air outlet. Use the proper fuse. 8. 9. 10. 11. 12. 13. 14. 15. 16. Avoid circuit or wire exposure. Do not operate the instrument with suspected failures.
RIGOL Safety Symbols on the Product: Hazardous Voltage Safety Warning Protective Earth Terminal English Chassis Ground Test Ground Care and Cleaning Care Do not store or leave the instrument where it may be exposed to direct sunlight for long periods of time. Cleaning Clean the instrument regularly according to its operating conditions. 1. Disconnect the instrument from all power sources. 2. Clean the external surfaces of the instrument with a soft cloth dampened with mild detergent or water.
RIGOL English Document Overview This manual introduces some basic information that you should know when you use the DP700 series power supply for the first time. It contains the following contents: out-of-box inspection method, product overview, how to connect the instrument to the AC power, procedures for carrying out the power-on inspection and output inspection, as well as remote control overview. Tip For the latest version of this manual, download it from RIGOL official website (www.rigol.com).
RIGOL General Inspection English 1. Inspect the packaging If the packaging has been damaged, do not dispose the damaged packaging or cushioning materials until the shipment has been checked for completeness and has passed both electrical and mechanical tests. The consigner or carrier shall be liable for the damage to the instrument resulting from shipment. RIGOL would not be responsible for free maintenance/rework or replacement of the instrument.
RIGOL English Product Overview DP700 series power supply is a type of affordable programmable linear DC power supply with high performance. With superb performance specifications, pure and reliable output, and clear user interface, the DP700 series supports timing output and trigger function, and provides a remote communication interface, enabling you to meet your diversified test requirements.
RIGOL English 7. AC Selector AC SELECTOR 1. Input Power Requirement 100Vac 120Vac 220Vac 6. Fuse Rating 240Vac FUSE RATING 100V T5A 120V 250Vac 220V 240V T2.5A 250Vac 5. Fuse Cap 2. AC Power Supply Connector 3. RS232 Interface 4. Air Outlet RIGOL TECHNOLOGIES,INC. MADE IN CHINA Figure 2 Rear Panel Note: Pin 7 and Pin 8 of the RS232 interface are not used in remote communication. They are used in the trigger function (optional). 1. Actual Output Mode 5. System Status Icons 2.
RIGOL English Power-on Inspection DP700 series power supply supports various specifications of AC input power. When the DP700 series is connected with different AC power supplies, the AC selector setting on the rear panel of the instrument is different, as shown in the table below.
RIGOL 5. Power on the instrument English Press the Power key , and then the instrument is launched and begins to perform the self-inspection. If the instrument passes the self-inspection, the welcome interface is displayed; otherwise, self-inspection failure information about corresponding items (including the analog board, OVP, OCP, fan, and temperature) will be displayed. Tip After powering off the instrument, please wait for at least 2 s to power it on again.
RIGOL output voltage is approximately 30 V, the actual output current approximately 0 A. English (5) Press On/Off to turn off the channel output. Check the current output: verify the basic current functions with a short across the power supply’s output. (1) Connect a short across the positive terminal (+) and negative terminal (-) of the channel output with an insulated test lead (18 AWG), and then press On/Off to turn on the channel output.
RIGOL Setting Methods for Output Voltage/Output Current: English Method 1: (1) Press the Up/Down arrow key to switch the parameter focus to "Voltage Voltage Setting Value Setting Value" or "Current Setting Value". Current Setting Value (2) Enter a value by using the num key. While entering a value, press to delete the unwanted character if necessary. (3) When setting the output voltage, press the Up arrow key or OK to set the voltage unit to V; or press the Down arrow key to set the voltage unit to mV.
RIGOL English Remote Control DP700 series power supply can be connected to the PC via the RS232 interface to set up communication and realize remote control through the PC. The remote control can be realized by using SCPI (Standard Commands for Programmable Instruments) commands. DP700 series power supply supports two ways of remote control: user-defined programming and PC software (e.g. RIGOL Ultra Sigma). When the instrument is in remote control, the icon is displayed on the user interface.