User Guide
RIGOL Chapter 4 Specifications
User’s Guide for DP1308A
4-2
Less than 50μs is spent on recovering the voltage within 15mV during the output
current changes from full load to half load or half to full.
Command Processing Time
[2]
<50ms
Temperature Coefficient per ℃(output percentage + offset)
Voltage
0.01%+2mV
0.01%+3mV
Current
0.02%+3mA
0.01%+0.5mA
Stability
[3]
± (output percentage + offset)
Voltage
0.03%+1mV
0.02%+2mV
Current
0.1%+3mA
0.05%+1mA
Voltage Programming Speed(to within 1% of total variation range)
Rising
Full Load
11ms
50ms
No Load
10ms
45ms
Falling
Full Load
13ms
20ms
No Load
200ms
400ms
OVP/OCP
Accuracy ± (output
percentage + offset)
0.5%+0.5V/0.5%+0.5A
Activation Time
1.5ms (OVP≥ 3V)
<10ms (OVP<3V and OCP)
Machine
Dimension
235 mm (W) x 155 mm (H) x 384 mm (D)
Weight
8.5 kg
Power Supply
AC Output
(50Hz-60Hz)
100Vac+10%, 115Vac+10%, 220Vac+10%,
230Vac+10%
Environment
Working Temperature
Full rated value output: 0℃~40℃
At higher temperature: the output current falls into
50% at the maximum temperature 55℃
Cooling Method
Fan cooling
Remarks:
[1] Specifications are for one hour warm-up and at 25℃.
[2] The maximum time required for regulating corresponding output when received APPLy and
SOURce commands.
[3] The variation of output within 8 hours after warm-up 30 minutes and both the load circuit and
environment temperature are in constant conditions.