Specifications
RIGOL
© 2008 RIGOL Technologies, Inc.
Programming Guide for DM3000 Series
2-5
1. :function
Syntax:
:function?
Function:
The command queries the kinds of measure functions.
Return Format:
The query returns the current DM3000 measure function’s shortening. The possible
returned values are: DCV, ACV, DCI, ACI, RESISTANCE, CAPACITANCE, CONTINUITY,
FRESISTANCE, DIODE, FREQUENCY, PERIOD, RATIO.
2. :function:voltage:DC:ratio
Syntax:
:function:voltage:DC:ratio
Function:
The command turns on DC voltage ratio measure function.
Remark:
In “:function?” , this function is corresponding to the returned value“ RATIO”.
3. :function:voltage:DC
Syntax:
:function:voltage:DC
Function:
The command turns on DC voltage measure function.
Remark:
In “:function?” , this function is corresponding to the returned value“ DCV”.
4. :function:voltage:AC
Syntax: