User manual
Chapter 10 Utility Functions and System Settings RIGOL
DG4000 User's Guide
10-5
Sync Mode
Set the output mode of the sync signal on the [Sync] connector at the front panel
to normal or carrier.
Press Utility CH1Set SyncMode to select "Normal" or "Carrier".
Normal: there are default operations for the [Sync] output. The operations
differ for different operation modes.
Carrier: only available in basic waveform mode (except noise and DC) and
infinite Burst mode. When the sync polarity is positive, [Sync] output is high
level within the first half of the period and is low level within the second half of
the period. When the sync polarity is negative, the [Sync] output is reverse
to that when the sync polarity is positive.
Output Polarity
Set the signal on the [Output1] connector as normal or inverted. Waveform
inverts relatively to the offset voltage.
Press Utility CH1Set Output to select "Normal" or "Invert". The default is
"Normal". In normal mode, the waveform is output normally; in invert mode, the
waveform is inverted and then output.
0 V Offset
0 V
Normal Invert Normal Invert
Pay attention to the following contents after the waveform is inverted:
None of the offset voltage would change.
Waveform is not inverted in graphic mode.
Sync signal related to the waveform is not inverted.