User manual
Chapter 7 Burst RIGOL
DG4000 User's Guide
7-5
then stops and holds on the voltage level corresponding to the initial burst phase
of the selected waveform. For Noise waveform, the output will stop immediately
once the gated signal becomes "False".
Gated Burst could only be triggered by "Ext" trigger source. Users can also set the
"Start Phase".
When Burst is enabled, press Type to select "Gated" and then press Polarity to
set the gated polarity as "Pos" (or "Neg"). The generator outputs burst waveform
only when the gated signal is "Pos" (or "Neg").
Figure 7-3 Gated Burst