User manual

Chapter 3 Arbitrary Waveform Output RIGOL
DG4000 Series Users Guide
3-15
Example: Edit Block
The following example introduces how to use Edit Block to create an arbitrary
waveform fulfilling the following conditions.
Parameter
Value
Cycle Period
12μs
High VLimit
4V
Low VLimit
-2V
Interp
Linear
X1Y1
2, 4V
X2Y2
4, -2V
Operation Procedures:
1. Press Arb and use to open the 2/2 menu page; then press Create New
Cycle Period, use the numeric keyboard to input 12 and select the unit
μs from the pop-up menu.
2. Press High VLimit, use the numeric keyboard to input 4 and select the unit
V from the pop-up menu.
3. Press Low VLimit, use the numeric keyboard to input -2 and select the unit
V from the pop-up menu.
4. Press Init #Points, use the numeric keyboard to input 4 and press OK.
Note: at this point, a -2 V level line appears.
5. Press Interp to select Linear.
6. Press Edit Block to enter the “Edit Block” interface.
1) Press X1 and use the numeric keyboard to input 2; then press Y1, use
the numeric keyboard to input 4 and select the unit V from the pop-up
menu. Use the same method to set X2 and Y2.