User manual

Chapter 8 Counter RIGOL
DG4000 Series Users Guide
8-5
Statistic
When the statistic function is enabled, the instrument calculates the maximum,
minimum, average and standard deviation of the measurement values
automatically and displays the variation tendency of the measurement values in
Digital or Curve mode.
1. To enable the statistic
Press Statist Statist to enable or disable statistic function and the default
is OFF.
2. To select display mode
After the statistic function is enabled, press Display to set the display mode
of the statistic result to Digital or Curve, as shown in Figure 8-2 and Figure
8-3.
Figure 8-2 Statistic results (in “Digital” display mode)