User Guide

RIGOL Chapter 6 Sweep
DG4000 Series Users Guide
6-10
End Hold
End Hold is the duration that the output signal outputs with the End Frequency
after the generator has swept from the Start Frequency to the End Frequency.
When Sweep is enabled, use to open the 2/2 menu page, then press End
Hold and use the numeric keyboard or knob to change the End Hold. The default
value is 0s and the available range is from 0s to 300s.
The generator will renewedly sweep and output from the specified start
frequency once the End Hold is changed.
Sweep Trigger Source
The Sweep trigger source could be internal, external or manual. The generator will
generate a sweep output when a trigger signal is received and then wait for the
next trigger.
When Sweep is enabled, use to open the 2/2 menu page and press Source
to select Int, Ext or Manual. The default is Int.
1. Internal Trigger
The generator outputs continuous sweep waveform. The trigger period is
determined by the specified sweep time, return time, start hold and end hold
times.
2. External Trigger
The generator accepts the trigger signal input from the [Mod/FSK/Trig]
connector at the rear panel. A sweep will be generated once the connector
gets a TTL pulse with specified polarity. To set the TTL pulse polarity, press
SlopeIn to select Leading or Trailing. The default is Leading.
Note that in Int and Manual trigger modes, the corresponding menu is
TrigOut. The [Mod/FSK/Trig] connector at the rear panel is used as the
output terminal of trigger signal.